Part Number Hot Search : 
25JE7TS MM3Z6V2 MHW92 MPX2700 AK8816VG WM9707 AP78L12V MB151
Product Description
Full Text Search
 

To Download MMK40S-12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 M e d i c a l G r a d e 4 0 Watt Enclosed Switching Power Supplies
MMK40s
series
Universal 90-264VAC Input Compact Footprint High Efficiency Regulated Outputs 4000V Isolation Built in EMI Filter
2.5"W x 4.75"L x 1.5"H
Model Number
MMK40S-5 MMK40S-12 MMK40S-15 MK40S-24
Output Voltage
5 VDC 12 VDC 15 VDC 24 VDC
Output Amps (max) Ripple/Noise pp,typ
8 3.5 2.8 1.8 50mv 120mv 150mv 120mv
Order On-Line!
WWW.AsTRODYNE.COM
astrodyne.com
300 Myles standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
M e d i c a l G r a d e 4 0 Watt Enclosed Switching Power Supplies
INPUT sPECIFICATIONs
Input Voltage Range Frequency Range Inrush Current, typ: 90-264 VAC 47-63 Hz 20A @ 115VAC Input * 40A @ 230VAC Input *
MMK40s
series
ENVIRONMENTAL sPECIFICATIONs
Oper. Temperature Over Temp Protection Storage Temperature Relative Humidity EMI (Designed to Meet) MTBF 0 to +60C (See Derate) Latching, recoverable after cooling and re-power -25 to +85 C * 10% to +95%, non-cond * EN55011, Class B IEC801-2,3,4 100 kHrs Mil Std 217, 25C
OUTPUT sPECIFICATIONs
Voltage and Current Load Regulation (0% to 100% Load) Line Regulation Preset Accuracy DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Short Circuit Protection Hold Up Time Turn On Time Rise Time Over/Under Shoot Leakage Current See Selection Chart 5V: 2% of FS, typ All Others: 0.5%, typ 0.5, typ 1%, typ 6% of FS 0.03%/C See Selection Chart Clamp * Indefinite 16mS, typ (Nom I/P, FL) 1.0 sec, typ 20 msec, typ < 10% of FS 0.3 mA @ 240VAC, 50 Hz
PHYsICAL sPECIFICATIONs
Size Construction Weight 4.75" x 2.5" x 1.5" Enclosed 9.6 oz, (272g)
GENERAL sPECIFICATIONs
Isolation I/P-O/P: 4000VAC I/P-Ground: 2500VAC O/P-Ground: 1000VAC 82%, typ 5V:76% 100Khz, (fixed, typical) UL60601-1, EN60601-1, IEC60601-1
Efficiency Switching Frequency Safety Approvals
All specifications are typical at nominal input, full load, and 25C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
WWW.AsTRODYNE.COM
300 Myles standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
M e d i c a l G r a d e 4 0 Watt Enclosed Switching Power Supplies
MECHANICAL DIMENsIONs Pin #
1 2 3 4 5
MMK40s
Outputs
ACL ACN GND + Output - Output
series
PLEASE NOTE: To improve specifications and safety isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit
OUTPUT DERATING CURVE
100 80 60 40 20
0
10
20
30
40
50 45
60 55
(VERTICAL) (HORIZONTAL)
WWW.AsTRODYNE.COM
300 Myles standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181


▲Up To Search▲   

 
Price & Availability of MMK40S-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X